Medical Equipment Repair in Baku
Medical equipment electronics repair in Baku — circuit board repair, sensor restoration and calibration for ultrasound (USG), X-ray, ECG, patient monitors, defibrillators, endoscopes, autoclaves and laboratory instruments.
Order
Send the make and model and describe the fault briefly. A video helps most — film the fault. Clear photos of the board help too.
Electronics repair for patient monitors, ultrasound (USG) scanners, X-ray units, ECG machines, defibrillators, endoscopes, autoclaves, dental chairs and laboratory instruments: control boards, sensors, high-voltage power supplies and calibration.
How we work



Not every device can be repaired
Sometimes restoration is not possible: the chip is discontinued and no spare can be sourced, no donor board is available, the board is severely damaged by fire or liquid, or earlier repair attempts have left it beyond recovery. In such cases we explain the situation plainly and, where possible, suggest an alternative.
With medical equipment, measurement accuracy comes before the repair itself: a device that powers on but reads incorrectly is unusable. That is why on ultrasound (USG) scanners, X-ray units, ECG machines and patient monitors we also carry out sensor and module calibration after the repair.
We work at component level — instead of swapping a whole module we do circuit board repair: a burnt high-voltage block, power supply, control board or sensor circuit is restored in place. That costs several times less than ordering a module from the manufacturer and shortens the wait.
The area also covers autoclave and steriliser electronics, endoscope light sources, laboratory centrifuges and incubators, and dental chair control units. Spare parts often have to be ordered in — we give the expected timeframe after diagnostics.
Devices we repair
Dedicated pages in this area
Common faults we repair
- The device will not power on or shuts itself down
- Image loss or banding on the ultrasound (USG) scanner
- High-voltage block failure on the X-ray unit
- ECG traces read incorrectly or drift
- Sensor and module calibration lost on the patient monitor
- Defibrillator no longer delivers energy
- Autoclave will not hold pressure, the cycle stops halfway
- Endoscope light source or camera module fault
- Power supply or internal UPS battery replacement
- Display and touch panel unresponsive
- Burnt pump or motor drive circuit
- Control board fault in a laboratory centrifuge or incubator
Typical causes of failure
- Failure of the power supply or the internal UPS battery
- Sensor calibration drifting out of tolerance
- Loss of contact in the touch panel and display ribbon
- Insulation breakdown in the high-voltage block (X-ray, spectrometer)
- A burnt pump or motor drive circuit
- Connector corrosion from disinfectants
Brands and platforms we work with
How the repair works
- 01
Enquiry and first contact
Tell us about the fault on WhatsApp or Telegram. We review what you send and let you know whether the device fits the work we take on.
- 02
Acceptance and diagnostics
If we can take the device on, we confirm it in advance — do not ship it before you have our confirmation. Once it reaches the lab, diagnostics are completed within 48 hours (two working days).
- 03
Estimate and approval
You receive a report covering the cause of the fault, the estimated cost, spare-part availability and the timeline. Work begins only after you approve it.
- 04
Testing and handover
After the repair the device runs a minimum 24-hour load test. Once it proves stable in normal operation, we report the result and hand it over.
Diagnostics and pricing
Diagnostics is paid work — 10–50 AZN depending on the complexity of the board. If you have us carry out the repair, that amount is deducted from the final price. An exact repair price is given only after diagnostics and is agreed with you before any work starts.
More about the diagnostic feeFrequently asked questions
Other repair areas
Request a repair
Message us on WhatsApp or Telegram with the BRAND and MODEL of the device and describe the fault in as much detail as you can. A VIDEO helps most: record the fault and explain in your own words what happens. Also send clear photos of the device and, if accessible, of the circuit board from several angles. The more detail you provide, the faster and more accurate our answer.